Street Lighting

We are pleased to be one of the first organisations to adopt the classification recommendations of the new ILE Technical Report 22, ‘Managing a Vital Asset: Lighting Supports’. Our test reports provide a classification format that allows the engineer to reduce the Priority Score on risk assessments as shown in the table below.
TR22
Category
CMT
Class
Average
LSUs
Recommendation TR22 - Priority Score Impact
2U 5 >-50 Immediate removal or making safe the unit No change
1U 4 -25 to -50 Schedule for removal/replacement as soon as practicable or in accordance with Operating Authorities Axtion Matrix No change
2G 3 -17 to -24 Re-test within 2 years Minus 2 from score
3G 2 -11 to -16 Re-test within 3 years Minus 3 from score
6G 1 0 to -10 Re-test within 6 years Minus 6 from score
CMT is UKAS accredited to BS/EN/ISO/IEC 17025.